Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 105 of 156 items found.

  • Transformer Winding Resistance Meters

    TWA Advanced Series - Amperis sl

    The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • LCR Meter

    TH2826 - Changzhou Tonghui Electronic Co., Ltd.

    TH2826 series is a new generation impedance test instrument and firstly in conformity with LXI standard inland. It fulfills most low-voltage parameter measurement needs for components and materials with its basic accuracy (0.1%), wide frequency range(from 20Hz to 5MHz). The instrument is widely applied in microphone, resonator, inductor, ceramic capacitor, LCD, varactor and transformer .etc to analyze electrical performance and test low-ESR capacitor and high-Q inductor. With the super high test speed, TH2826 series is especially for frequency response curve analyzing of detector and piezoelectric device on auto production line. Its multiple output impedance mode can be used for different standards of inductor or transformer manufacturers.

  • LCR Meter

    TH2826A - Changzhou Tonghui Electronic Co., Ltd.

    TH2826A is a new generation impedance test instrument and firstly in conformity with LXI standard inland. It fulfills most low-voltage parameter measurement needs for components and materials with its basic accuracy (0.1%), wide frequency range(from 20Hz to 2MHz). The instrument is widely applied in microphone, resonator, inductor, ceramic capacitor, LCD, varactor and transformer .etc to analyze electrical performance and test low-ESR capacitor and high-Q inductor.    With the super high test speed, TH2826A is especially for frequency response curve analyzing of detector and piezoelectric device on auto production line. Its multiple output impedance mode can be used for different standards of inductor or transformer manufacturers.

  • Digital Tap Position Indicator With Voltage &Counter Display

    Neutronics Manufacturing Co.

    NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.

  • Switchgear PD Monitoring System

    PD Alarm - IPEC Ltd.

    The PD Alarm™ is an asset mounted device for indicating the presence of partial discharge in high voltage switchgear, ring main units (RMUs) and dry type transformers. Designed for use in small substations, the instrument can activate local and remote alarms in addition to local indication.

  • Surge Arrester Testing

    Weshine Electric Manufacturing Co., Ltd

    This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.

  • Low-Voltage Arrester Analyzer

    Weshine Electric Manufacturing Co., Ltd

    1. This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.

  • 10 A portable digital micro-ohmmeter

    MPK-253 - MEGABRAS srl

    The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.

  • Primary Test Manager

    OMICRON electronics

    The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).

  • 5 A portable digital micro-ohmmeter

    MPK-254 - MEGABRAS srl

    The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.

  • Time Interval Meter

    NEO TELE-TRONIX PVT. LTD

    Highly experienced in this industry, we are a well recognized manufacturer and exporter of Time Interval Meter. Supplied to electrical, power and engineering industry for instrument transformer and switchgear testing, this instrument is available to clients in different technical specifications. We use certified quality raw materials and components, procured from trusted vendor in market. We offer this Time Interval Meter (1 & 3 Channel) to clients at competitive price.

  • PD Surveyor with RFI & EMI Diagnostics

    PDS200 - Doble Engineering

    The Doble PDS200 is a combination survey tool that uses radio frequency interference and electromagnetic interference diagnostics to find signs of partial discharge.This hand-held instrument is an ideal tool for a condition based maintenance program, allowing you to quickly find insulation defects in motors, generators, transformers, cable terminations and additional substation components.

  • AC Voltage And Current Testing

    Shanghai Jiuzhi Electric Co., Ltd.

    AC voltage and current test system is used to be the electrical test performed on a component (such as, bushings, arrestors, insulating materials) or high voltage products (such as, high voltage cables, power transformers, instrument transformers, gas insulated switchgears, air insulated switchgears, high voltage insulators and etc) to determine the effectiveness of its insulation. For the safety of high voltage transmission , testing insulation integrity is essential for all high voltage products.

  • Tap Changer Analyzers & Winding Ohmmeters

    IBEKO Power AB

    Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints